Call Now
Website
Call
Business Details
13 Years
experience
Dynamic Pile Testing Services
Nagy Engineers, Inc. is a specialized pile testing company founded in 2013 by Matthew Nagy, a licensed professional engineer with over 15 years of expertise in deep foundation analysis. Our team delivers advanced dynamic pile testing, wave equation analysis, and non-destructive integrity testing for deep foundations across the Gulf Coast region. We utilize cutting-edge technology like the Pile Driving Analyzer (PDA) and CAPWAP software to provide precise evaluations of pile capacity, soil resistance, and structural integrity. Our services support commercial, industrial, transportation, and flood protection infrastructure projects, ensuring compliance with engineering standards and project-specific requirements.

With operations based in Slidell, Louisiana, we serve clients in Louisiana, Mississippi, Alabama, Arkansas, and Texas, combining technical proficiency with localized industry knowledge. Our founders background includes five years working with pioneers of PDA technology, establishing a foundation of innovation and technical rigor. We prioritize accurate data collection, transparent reporting, and collaboration with clients to optimize foundation performance and safety. Our certifications, including Master Level PDA Certification from the Pile Driving Contractors Association, underscore our commitment to excellence in deep foundation testing.
Services
Dynamic Pile Testing WEAP Wave Equation Analysis Thermal Integrity Profiling Cross-Hole Sonic Logging Pile Integrity Testing
Details
  • Year established: 2013
Highlights and features
  • We offer 15+ years of deep foundations industry expertise.
  • Our team holds Master Level PDA Certification from PDCA.
  • We specialize in Gulf Coast geotechnical conditions.
  • We provide comprehensive testing from initial drive to restrike.
  • Our methods combine PDA, CAPWAP, and thermal integrity profiling.
Associations and certifications
  • Pile Driving Contractors Association (PDCA)
Services
Dynamic Pile Testing
Dynamic Pile Testing evaluates pile integrity and capacity using strain and acceleration sensors during hammer impacts. Force and velocity data are analyzed with CAPWAP software to refine capacity estimates. This method ensures accurate assessment of driving stresses, hammer energy transfer, and long-term soil setup effects for deep foundation projects.
WEAP Wave Equation Analysis
WEAP simulates pile driving behavior to select optimal hammer types and sizes. It predicts driving stresses and capacity for Bearing Graph or Driveability Analyses. This tool aids in establishing driving criteria, though field validation with PDA testing is recommended for accuracy in complex soil conditions.
Thermal Integrity Profiling
Thermal Integrity Profiling uses embedded sensors to monitor concrete curing temperatures in drilled shafts. Variations detect defects like necking or bulging, displayed in 3D models. This non-invasive method ensures quality control for augercast piles and cast-in-place foundations during construction.
Cross-Hole Sonic Logging
Cross-Hole Sonic Logging assesses concrete quality in drilled shafts using ultrasonic signals between access tubes. Consistent signal arrival times indicate uniform concrete, while delays highlight potential flaws. This method ensures structural integrity for critical infrastructure projects requiring high-load-bearing foundations.
Pile Integrity Testing
Pile Integrity Testing determines unknown foundation lengths via stress wave reflections. Using the Pulse Echo Method, it identifies discontinuities or changes in cross-section. This rapid, cost-effective technique evaluates existing piles for retrofitting or forensic analysis in varied geotechnical conditions.
People
Matthew Nagy
Founder & President
Matthew Nagy, P.E., founded Nagy Engineers in 2013 after 15 years in deep foundations. A University of Cincinnati graduate, he holds licenses in five Gulf Coast states and PDCAs Master Level PDA Certification. His expertise includes dynamic testing for levees, bridges, and industrial projects.
Questions
What is dynamic pile testing?
Dynamic pile testing measures pile capacity and integrity during driving using sensors and the Pile Driving Analyzer® (PDA) to assess force, velocity, and soil resistance.
How does Thermal Integrity Profiling work?
TIP uses embedded thermal sensors to monitor concrete curing temperatures, detecting defects like necking or bulging in drilled shafts through 3D modeling of temperature variations.
What areas do you serve?
We specialize in Gulf Coast states: Louisiana, Mississippi, Alabama, Arkansas, and Texas, focusing on regional geotechnical and infrastructure challenges.
What certifications do you hold?
Our team holds Master Level PDA Certification from the Pile Driving Contractors Association, ensuring adherence to industry-leading testing standards.
Can you test existing foundations?
Yes, we perform Pile Integrity Testing (PIT) and Parallel Seismic Testing to evaluate unknown lengths and structural integrity of existing deep foundations.
Why use CAPWAP analysis?
CAPWAP refines pile capacity estimates by matching field data to soil resistance models, improving accuracy for long-term performance predictions after dynamic testing.